Safety Analyser Series
 
The SA-2000 Series is a Microprocessor based Electrical Safety Analyzer Family. There are 5 models that provide everything from the most basic testing functions to the most complete set of features of any handheld unit on the market. The compact size makes the SA-2000 Family easy to hold and operate. All models operate from 85 to 265 Volts @ 50/60 Hz, with Load Currents up to 20 Amps, so there is no need to purchase 2 different analyzers to cover your testing needs. The SA-2010S is the smallest safety analyzer available with a built-in ECG Patient simulator. The SA-2000 Family of Safety Analyzers allows the user to chose the model that best fits the application. The combination of the best features at the best price makes this Family of products a natural choice. All models come with a soft case and Chassis (Black) cable. An optional External Point-to-Point (Red) cable is also available.
 
Features
  • Small Self Contained Package
  • Line Voltage Measurement
  • Device Under Test Current Measurement
  • Earth/Ground Lead Resistance/
  • Leakage Current
  • Point-to-Point Testing
  • Enclosure/Chassis Leakage Current
  • External Resistance
  • External Leakage Current
  • Source Receptacle Wiring Integrity
  • Monitor
  • MAP (Isolation) Function
  • Soft Carrying Case Optiional
  • External Point-to-Point (Red) Cable
  • Built-In ECG Simulator
  • True RMS Measurements
  • AAMI ES1-1993 or IEC 601 Selectable
  • Test Loads
  • 85 to 265 VAC Operation
  • Full 20 amp Rating
  • Touch Control Keys - No Knobs
  • LED Status Indicators
  • Audio Feedback
  • Self-Test Points
  • Externally Replaceable Ground Fuse
  • Automatic Load Reversal Delay
1.gif

 
Patient Simulator Series
 
The PS-2200 Multi-Parameter Patient Simulator Series is the most comprehensive , easy to use simulator on the market. These new portable simulators are intuitive to use since there are NO MORE CODES to enter. Each model provides ECG, Blood Pressure, Respiration and Temperature Simulation. Models are available with one, two or four independent blood pressure outputs. All models will support the Fetal/Maternal, SpO2,
Cardiac Output and PSR-2200 Remote options.

The PS-2200 Series makes viewing and selecting the desired waveforms and parameters quick and intuitive. All operational information is available at the same time on two cursor-based graphic displays, allowing for easy maneuvering through parameters and scrolling through available options
 
Features
  • Simple to Operate
  • 12 Lead ECG Simulation
  • Independent ECG Outputs
  • 1, 2 or 4 Invasive BP Channels
  • All BP Waveforms Available on all BP Channels
  • 49 Arrhythmia Selections
  • Respiration & Temperature Simulation
  • ECG Performance Waveforms
  • Dual Graphical Backlit Displays
  • Drop Down Choice Screens List all
    Options for Parameters
  • Special Power Up Feature Allows User to choose to Use Default, Last or Custom Settings
  • Auto Sequences for BPM,
  • Static-Pressure Levels & Performance
  • SpO2 Simulation
  • 10 Universal Patient Lead Connectors (Extra Space Between Posts for the Largest Connectors)
  • Mini DIN Connectors Compatible with Standard BP Cables (Optional Mini DIN-M to DIN-F Cable Adapter)
  • % Battery Life Display & Low Battery
  • Indicator
  • Powered by Two 9V Batteries or Optional Battery Eliminator
  • Full Remote Operation via RS232
  • Flash Programmable for Upgrades
    Optiional
  • Cardiac Output
  • Fetal/Maternal
  • Remote PSR-2200
  • Battery Eliminator
2.gif

 
Defibrillator Analysers
 
The DA-2006 is a Microprocessor based instrument that is used in the testing of defibrillators. It measures the energy output andprovides information about the pulse. It is used on manual, semi-automatic and automatic defibrillators with monophasic or biphasic outputs.

The DA-2006P model additionally provides a Transcutaneous Pacemaker analysis function. It measures and displays pacer pulse information as well as performing Refractory Period, Sensitivity and Immunity testing. The DA-2006P provides unique spark gap protection for the pacer input to help avoid internal damage from accidental defib. Internal Paddle Adapters, Battery Eliminator and Protective Plates included with unit purchase
 
Features
  • Biphasic Energy Measurement
  • Fully AED Compatible
  • Simple to Operate
  • Graphics Display with Simultaneous detailed Status of Parameters & Scrolling Control of options
  • On-Screen Viewing of Defib Waveform
  • Drop Down Choice Screens List All Options for Parameters
  • Monophasic & Biphasic Compatible
  • 5000 V, 1000 Joule Capacity
  • High & Low Ranges
  • Cardioversion Delay Measurement
  • Charge Time Measurement
  • Waveform Storage & Playback
  • 10 Universal Patient Lead connectors
  • 25 PIN Connector for Centronics
  • Printer
  • Two 9V Battery Power (Battery Eliminator Furnished)
  • Low Battery Indicator
  • Display Backlight
  • Full Remote Operation via RS232
  • Flash Programmable for Upgrades
Features -- DA--2006P
  • 26 Selectable Internal Loads
  • Full Pulse Analysis
  • Demand Sensitivity Test
  • Refractory Period Tests
  • 50/60 Hz Interference Test Signals
  • Pacer Input Defib Protection
3.gif

 
NIBP Simulators
 
 The NIBP-1000 Series is a new Family of high quality, low cost, high function Microprocessor based NIBP Simulators. They were designed to meet the demand for a small, easy to use unit with multiple features to fit your exact needs.

Though small, this Family makes no compromiseon providing true outputs. The optional ECG waveforms are full QRS & the respiration waveforms look real.

The graphic display not only allows you to see what is going on digitally, it also allows you to view a plot of the overall pressure or a close-up of the BP waveform. The Flash Memory allows for field upgrades with downloads from our website.
 
Features
  • Small Self Contained Package
  • Low Cost
  • Simple to Operate
  • 0 to 500 mmHg Manometer
  • ±1% of Reading Pressure Accuracy
  • Large Graphics Display with Cursor
  • Selection of Options & Setup of
  • Parameters
  • Software Adjustable Contrast
  • Total Pressure & BP Waveform Displays
  • Adult, Neonatal & Hypertensive Modes
  • SpO2 Ready-Compatible with MSP-2100
  • Module & FingerSimsTM
  • Digital Calibration-No Pots to Turn
  • Multiple Display Screens & Digit Sizes
  • Flash Programmable for Upgrades
  • RS232 Interface 
Optional
  • Peak Pressure Detection with Easy Reset
  • Rechargeable NiMH Batteries - Internal
ECG Model Additional Features
  • ECG Output with Full NSR Waveform
  • Sinusoidal Respiration Simulation
  • ECG Performance Test Waveforms
  • Pace Waveform
  • ECG Alarm Test
4.gif

 
Pressure Meters
 
The DPM-2000 Series is a Microprocessor based Family of Meters that offers not only positive & negative pressure sensing of compatible
liquids & gases, but also has models with Temperature & RS232. All of the DPM-2000 models measure positive and negative pressure and are compatiblewith both liquids and gases.

The DPM-2001 is the base model. The DPM-2001 PLUS adds a "Min/Max" feature plus an RS232 port. The top-of-the-line DPM-2100 is a pressure/temperature meter. It has all the features of the PLUS model and also includes a YSI 700 temperature probe interface.

Each model has a battery life display (0 to 100%), LCD contrast is software adjustable,digital calibration-no pots to turn, .1% of full scale accuracy, -13.50 to 100.00 PSI range digital zero adjust and four pressure scales: PSI, inH2O, cmH2O and mmHG.
 
Features
Basic Features - DPM-2000 Series
  • 5 Digit LCD Display
  • Programmable Digital Filter
  • Digital Calibration & Zero Adjust
  • Male Luer Connector
  • Small self contained package (7" x 4" x 1.5")
  • Battery Life Display (0 to 100%)
Pressure Ranges:
  • 13.50 to 100.00 PSI
  • 698 to 5171 mmHg
  • 950 to 7037 cm H2O
  • 374 to 2771 inches H2O
  • 0.1% FS Pressure Accuracy
Features - DPM-2001PLUS
Has all of the features of the DPM-2001, PLUS:
  • Min/Max Pressure Value Capture
  • RS232 Serial Communications
Features - DPM-2100
Has all of the features of the DPM-2001, PLUS:
  • YSI 700 Temp Probe Interface
  • +32.0º to +212.0ºF Temp Range
  • 0.5% FS Temp Accuracy
  • Min/Max Temp Value Capture
  • Min/Max Pressure Value Capture
  • RS232 Serial Communications
5.gif

 
Infusion Pump Analyser
 
The IPA-1000 Infusion Pump Analyzer Family is designed to test the flow rates of intravenous infusion pumps to ensure their correct operation. It is able to test up to two pumps simultaneously by the volumetric method in milliliters per hour. All tests are controlled by a Microprocessor which calculates and displays the results. The fluid path is unobstructed, making them easy to clean. The tubes are plastic, not glass so they are rugged. The cables and chambers are interchangeable. The unit auto identifies each chamber when it is plugged in. The chamber calibration is stored electronically in each chamber, so all units are interchangeable. This unit is designed to be tough, simple, portable & very user friendly.
 
Features
  • Easy to Use
  • Easy to Clean
  • Simultaneous Operation of Two Chambers
  • Large Graphics Display with Cursor
  • Selection of Options & Setup of Parameters
  • Auto Chamber Recognition
  • 2 Chamber Sizes (3.5 & 35 mL)
  • Out of Sequence Sensing
  • Battery Display (0 to 100%)
  • Similar Function to Dynatech Nevada
  • Model 404A
  • Ranges 0 to 999.9 mL/hr & 0 to9999 mL/hr
  • ±1% of Reading Flow Accuracy
  • Digital Calibration - No Pots to TurnSoftware
  • Adjustable Contrast
  • Replaceable Tubes
  • Sealed Level Sensors
  • Programmable End of Test Audio
  • Programmable Auto or Manual Test Start
Optional
  • Battery Eliminator
6.gif